Notice: Undefined offset: 1 in /home/jackycho/public_html/hungtatester.com/wp-content/themes/replete/framework/php/function-set-avia-frontend.php on line 1015

Emergency Automatic Locking Tester
This tester can generate an acceleration at a selectable certain level within 50 mili-seconds in order to test if the retractor is of good quality.

Modle HT-9313
Type of test Webbing sensing
Testing range 2.94 (m/sq.s) {0.3 g}, (6.86 m/sq.s) {0.7 g}
14.7 (m/sq.s) {1.5 g}, (19.6 m/sq.s) {2.0 g}
Testing angle ±35°
Location of webbing Direction of acceleration: Pull out direction of webbings
should be within 25% of its effective length
Installing angle of retractor Standard angle of automobile
Direction of acceleration: Pull out direction of webbings
Air cylinder 1 set
Stroke 100 mm
Pressure accumulator 1 set
Display of locking distance distance ruler 1 set
Optional items computer hardware 1 set
G value sensor 1 set
Locking sensor 1 set
exclusive test program 1 set