ROUNDNESS TESTER CV-EC2500

PC controlled roundness measuring system

Technical specifications

Standard delivery

  • Measuring unit
  • Standard probe
  • Controller
  • Programm software

Optional accessories

  • PC with monitor
  • Interchangeable styli for different
    applications:
  • Ask for separate overview
  • Chucks ø 0.8 ~ 56mm used for clamping small diameter workpieces
  • Reference hemisphere for checking accuracy
    Printer
Stage  
Rotating method Porus static air bearing / stage rotation
Rotating accuracy (0.02+0.0003H)µm H: Height from stage (mm)
Rotating speed 1 to 10rpm
Stage size 260mm dia
Centering adjustment range ?mm (Motorized)
Leveling adjustment range ??(Motorized)
Max. workpiece load 30kg
Max. workpiece diameter 450mm
Column unit  
Straightness 0.15µm/100mm (0.4µm/300mm)
Parallelism 0.8µm/200mm
Vertical travel 400mm
Travelling speed 0.5, 1, 2 and 5mm/s at measuring, 20mm/sec at positioning
Max. measuring height 570mm for outer, 420mm for inner
Radial arm unit Radial travel: 180mm
Pick up unit  
Measuring force 100mN or less (adjustable)
Measuring range 1800µm
Stylus Radius 0.8mm, Tungsten carbide
Analysis unit  
Measuring magnification 100, 200, 500, 1K, 2K, 5K, 10K, 20K, 50K, 100K
Digital filter  
Roundness 2CR N15, N50, N150, N500, N15-500, non-filter
Gaussian D15, D50, D150, D500, D15-500, non-filter
Straightness 2CR fh0.025, 0.08, 0.25, 0.8, 2.5, 8mm, non-filter
Gaussian fh0.025, 0.08, 0.25, 0.8, 2.5, 8mm, non-filter
Determination method MZC, LSC, MCC, MIC
Analysis items Roundness, flatness, cylindericity, co-axiality, concentricity,
  run-out, squareness, straightness, parallelism, thickness deviation
Utilities  
Power Supply AC100V, ?0%, 50/60Hz, 1KVA
Air pressure at bearing 4 to 5kgf/cm²G (390 to 490KPa), 30Nl/min
Air Supply 4.5 to 9.9kgf/cm²G (440 to 970KPa), Dry air
Dimensions  
Measuring unit 930mm x 590mm x 1660mm (WxDxH), 550kg
Amplifier 406mm x 342mm x 270mm (WxDxH), 20kg
PC and printer Local supply
Operating environment 10°C to 30°C, RH 80% or less